Main menu:

EN 1015 – 10/11/12

The BAM ( German Federal Institute of Materials Research and Tests ) certified BionicPore to be conform to the European Norm DIN EN 998-1.

The BAM performed the following tests : DIN EN 998-1 Specification for mortar for masonry – Rendering and plastering mortar

  • DIN EN 1015 Methods of test for mortar for masonry
  • Part 10 Determination of dry bulk density of hardened mortar
  • Part 11 Determination of flexural and compressive strength of hardened mortar
  • Part 12 Determination of adhesive strength of hardened rendering and plastering mortar

with the following results:

Dry Bulk Density

Test

Dry mass ms,seco[kg]

Volume Vs (m3)

Dry Bulk Density Single Values [kg/m3]

Dry Bulk Density

Mean value [kg/m3]

1

0.400

258.10-6

1550

1590 ± 30

2

0.401

256.10-6

1560

3

0.405

257.10-6

1580

4

0.418

257.10-6

1620

5

0.417

257.10-6

1620

6

0.412

258.10-6

1600

Flexural and Compressive Strength

Test

Bulk Density [kg/ m3]

Fracture Load (N)

Flexural Strength [MPa]

Compressive Load [kN]

Compressive Strength [MPa]

1

1550

1376

3.2

15.2

15.2

9.5

9.5

2

1540

1343

3.1

15.5

15.6

9.7

9.8

3

1510

1352

3.2

14.9

15.3

9.3

9.6

4

1610

1562

3.7

18.5

18.1

11.6

11.3

5

1600

1424

3.3

17.8

19.0

11.6

11.3

6

1590

1363

3.2

17.2

19.0

10.8

11.9

Mean

1570

3.3

10.5

Deviation

0.2

1.0

Adhesive Strength

Test

Pull-off Load [N]

Adhesive Strength (N)

Failure Type

1

790

0.40

B

2

680

0.35

B

3

640

0.35

B

4

650

0.35

A

5

790

0.40

B

Mean

710

0.4

Deviation

0.05