EN 1015 – 10/11/12
The BAM ( German Federal Institute of Materials Research and Tests ) certified BionicPore to be conform to the European Norm DIN EN 998-1.
The BAM performed the following tests : DIN EN 998-1 Specification for mortar for masonry – Rendering and plastering mortar
- DIN EN 1015 Methods of test for mortar for masonry
- Part 10 Determination of dry bulk density of hardened mortar
- Part 11 Determination of flexural and compressive strength of hardened mortar
- Part 12 Determination of adhesive strength of hardened rendering and plastering mortar
with the following results:
Dry Bulk Density
Test |
Dry mass ms,seco[kg] |
Volume Vs (m3) |
Dry Bulk Density Single Values [kg/m3] |
Dry Bulk Density Mean value [kg/m3] |
1 |
0.400 |
258.10-6 |
1550 |
1590 ± 30 |
2 |
0.401 |
256.10-6 |
1560 |
|
3 |
0.405 |
257.10-6 |
1580 |
|
4 |
0.418 |
257.10-6 |
1620 |
|
5 |
0.417 |
257.10-6 |
1620 |
|
6 |
0.412 |
258.10-6 |
1600 |
Flexural and Compressive Strength
Test |
Bulk Density [kg/ m3] |
Fracture Load (N) |
Flexural Strength [MPa] |
Compressive Load [kN] |
Compressive Strength [MPa] |
1 |
1550 |
1376 |
3.2 |
15.2 15.2 |
9.5 9.5 |
2 |
1540 |
1343 |
3.1 |
15.5 15.6 |
9.7 9.8 |
3 |
1510 |
1352 |
3.2 |
14.9 15.3 |
9.3 9.6 |
4 |
1610 |
1562 |
3.7 |
18.5 18.1 |
11.6 11.3 |
5 |
1600 |
1424 |
3.3 |
17.8 19.0 |
11.6 11.3 |
6 |
1590 |
1363 |
3.2 |
17.2 19.0 |
10.8 11.9 |
Mean |
1570 |
|
3.3 |
|
10.5 |
Deviation |
|
0.2 |
|
1.0 |
Adhesive Strength
Test |
Pull-off Load [N] |
Adhesive Strength (N) |
Failure Type |
1 |
790 |
0.40 |
B |
2 |
680 |
0.35 |
B |
3 |
640 |
0.35 |
B |
4 |
650 |
0.35 |
A |
5 |
790 |
0.40 |
B |
Mean |
710 |
0.4 |
|
Deviation |
0.05 |
|